Search results for "Ozone monitor"
showing 7 items of 7 documents
Operational considerations to improve total ozone measurements with a Microtops II ozone monitor
2012
A Microtops II "ozone monitor" with UV channels centered at 305.5, 312.5, and 320 nm has been used routinely in six experimental campaigns carried out in several geographic locations and seasons, covering latitudes from 35 to 68° N during the last ten years (2001–2011). The total ozone content is retrieved by Microtops II by using different combinations (Channel I, 305.5/312.5 nm; Channel II, 312.5/320 nm; and Channel III, 305.5/312.5/320 nm) of the signals at the three ultraviolet wavelengths. The long-term performance of the total ozone content determination has been studied taking into account the sensitivities to the calibration, airmass, temperature and aerosols. When a calibration was…
Analysing time-varying trends in stratospheric ozone time series using the state space approach
2014
Abstract. We describe a hierarchical statistical state space model for ozone profile time series. The time series are from satellite measurements by the Stratospheric Aerosol and Gas Experiment (SAGE) II and the Global Ozone Monitoring by Occultation of Stars (GOMOS) instruments spanning the years 1984–2011. Vertical ozone profiles were linearly interpolated on an altitude grid with 1 km resolution covering 20–60 km. Monthly averages were calculated for each altitude level and 10° wide latitude bins between 60° S and 60° N. In the analysis, mean densities are studied separately for the 25–35, 35–45, and 45–55 km layers. Model variables include the ozone mean level, local trend, seasonal osc…
Validación de los datos de radiación solar UV del Ozone Monitoring Instrument (OMI) a partir de medidas con base en tierra en la costa mediterránea
2016
<p align="justify">The erythemal UV daily dose (EDD) and the local noon UV Index (UVI) obtained from the Ozone Monitoring Instrument (OMI), on board NASA’s Aura satellite, have been validated for the period 2005-2013 using ground based measurements at 5 different sites in the Mediterranean coast: Murcia, Valencia, Palma de Mallorca, Barcelona and Rome (where only measurements of the local noon UVI were available). Ground based measurements were made using YES UVB-1 radiometers in Murcia, Valencia, Palma de Mallorca and Barcelona, and a Brewer MKIV 067 spectrophotometer in Rome. The results of the validation showed good agreement between the satellite instrument and the ground based me…
Stratospheric sulfur and its implications for radiative forcing simulated by the chemistry climate model EMAC
2015
Multiyear simulations with the atmospheric chemistry general circulation model EMAC with a microphysical modal aerosol module at high vertical resolution demonstrate that the sulfur gases COS and SO2, the latter from low-latitude and midlatitude volcanic eruptions, predominantly control the formation of stratospheric aerosol. Marine dimethyl sulfide (DMS) and other SO2 sources, including strong anthropogenic emissions in China, are found to play a minor role except in the lowermost stratosphere. Estimates of volcanic SO2 emissions are based on satellite observations using Total Ozone Mapping Spectrometer and Ozone Monitoring Instrument for total injected mass and Michelson Interferometer fo…
Improvement of the Valencia region ultraviolet index (UVI) forecasting system
2012
The CEAM Foundation (Valencia, Spain) has developed an operational ultraviolet index (UVI) forecasting system based on the Santa Barbara DISORT Atmospheric Radiative Transfer (SBDART) model. The main objective of this system is to provide the general public with a tool to minimize the impact of ultraviolet (UV) radiation, which can cause important human health problems. The system presented in this paper has been developed in collaboration with the Environment Department of the Regional Government of Valencia, and it replaces the one running until 2007. The new system substitutes the previously used Ozone Monitoring Instrument (OMI) observed data with the total ozone column data forecasted …
Measurements of total ozone amount over Badajoz (Southwestern Spain) by means of a GUV multiband radiometer
2012
This paper presents the first measurements of total ozone amount performed at the radiometric station of Badajoz (Spain) by means of a multichannel radiometer GUV-2511. The retrieval of total ozone amount from GUV measurements of solar ultraviolet irradiance is performed with the support of look-up tables calculated using the SBDART radiation transfer code. This methodology is based on the different absorption by ozone suffered by the radiation at two certain near wavelengths. In this case the pair 305, 340 nm was chosen because of its better performance than the pair 305, 320 nm. The look-up table contains the ratio between irradiances at the mentioned wavelengths calculated under differen…
Suitability of OMI aerosol index to reflect mineral dust surface conditions: preliminary application for studying the link with meningitis epidemics …
2013
12 pages; International audience; The aimof this study is to analyze the suitability of remotely-sensed aerosol retrievals to progress in the understanding of the influence of desert dust on health, and particularly on meningitis epidemics. In the Sahel, meningitis epidemics are a serious public health issue. Social factors are of prime importance in the dynamics of the epidemics, however climate and environmental factors are also suspected to play an important role. This study focuses on three Sahelian countries (Burkina Faso,Mali and Niger) which are among the most concerned in the "meningitis belt" and affected by strong dust events every year. It investigates the capability of the aeros…